WIRING

Refer to Figures 5 and 6.
All wiring must comply with local codes and unit must be properly
grounded.
1. Run 120vAC house wiring from power source, through wall switch, to
junction box in housing.
2. To control both fan and light with one switch, install wiring.
3. For separate control of the fan and light, use NuTone double switch and
install wiring.
4. Install approved box connector into wiring access hole. String wires
through box connector and into junction box.
5. Use approved wire nuts to make wire connections. Green or bare supply
ground lead must be connected to green lead in wiring compartment.

POWER/BLOWER UNIT INSTALLATION

Refer to Figure 1.
1. Place power/blower unit into housing so that mounting plate's tabs insert
into slots in housing.
2. Secure mounting plate with provided screw.
3. Insert motor plug into junction box receptacle.

COMPLETING INSTALLATION

Refer to Figure 1.
1. Remove acorn nut from the threaded stud on motor mounting plate.
2. Place reflector into grille.
3. Align grille/reflector assembly with housing and insert light plug into
receptacle in junction box.
4. Using acorn nut, secure grille/reflector assembly to motor mounting
strap.
5. Install 100 watt (maximum) light bulb into light socket.
6. Install lens by squeezing both sides and inserting lens tabs into slots in
grille.
WARRANTY OWNER: Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or
workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use
and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER
ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied
warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT
OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to
state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Date of Installation
Builder or Installer
Model No. and Product Description
One Year Limited Warranty
IF YOU NEED ASSISTANCE OR SERVICE - CONTACT:
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
Broan-NuTone Canada Mississauga, Ontario www.nutone.ca 877-896-1119
INSTALLATION IN EXISTING
CONSTRUCTION
PLANNING
Installing a bathroom exhaust fan-light in a finished house requires
at least a small accessible area (attic or crawl space) above the
planned installation location.
Plan ducting and wiring before proceeding with installation (see
page 1).
CAUTION: Check area above planned location to be sure that:
(1) Ducting can be installed
(2) Wiring can be run to the planned location
(3) No wiring or other obstruction might interfere with installation
INSTALLATION
1. The fan light can be mounted directly to a ceiling joist or spaced
between joists using hanger bars (sold separately). If housing is to
be mounted directly to ceiling joist plan cutout so side of housing
with mounting tabs is against joist.
LOCATING JOIST: Lightly tap the ceiling. A hollow sound means
no joists, a solid sound means a joist is present. To be sure you
have located a joist, drill a small hole (1/16") and probe into the
ceiling with a wire. Leave wire in hole to help locate it in the attic or
crawl space.
2. Locate hole in attic or crawl space.
3. Using the housing as a template, mark the ceiling for the cutout.
Cutout dimensions: 9
/
" x 9
1
8
4. Make cutout along marked line.
5. Refer to Mounting The Housing on page 2.