56 Nortel Ethernet Routing Switch 2500 Series stacking
CFG mirror image process
The CFG mirror image process is triggered by specific events.
Power Cycle After a power cycle, all the CFG images in a stack are
mirrored.
Figure 15 "CFG mirror process in stack" (page 56)
images in a three-unit stack after the stack is powered on. Unit 1 is the
Based Unit (BU) and all other units are Non-Based Units (NBU).
Figure 15
CFG mirror process in stack
Copyright © 2007, Nortel Networks
.
Unit 1 (BU) contains mirror images for unit 2 (CFG 2) and unit 3 (CFG 3).
Unit 2 (NBU), is the TEMP-BU. It contains a mirror image of unit 1 (CFG
1), in case the BU (unit 1) is removed from the stack.
All three mirror images (CFG 1, CFG 2, and CFG 3) are active.
Unit 2 is the Associated Unit of the CFG 2 mirror image.
The Mac Address 2 is the Associated Mac Address (AMA) of the CFG
2 mirror image.

Nortel Ethernet Routing Switch 2500 Series

Overview — System Configuration

NN47215-500 (323162-B) 02.02 Standard

4.1 19 November 2007
illustrates the CFG mirror