Optical Pats Disassemblies
c
Condenser lens disassembly
1
A
Remove 2 screws
(M2.5x6) and pull the Condenser Lens ass'y upward.
2
B
Remove 4 screws
(M2x4) to take the Lens off from the holder.
A
v
Condenser Lens-Out disassembly
1
A
Remove 2 screws
(M2.5x6) and pull the Condenser Lens-Out ass'y
upward.
2
B
Remove 2 screws
(M2x4) to take the Lens off from the holder.
Note:
Should be place the lens as shown in the figure.
A
Fig.3-
A
A
Fig.4-
B
B
* Lens should be placed as the flat
surface side comes to the holder
side.
1
B
B
Condenser Lens-Out
1
-15-
B
Condenser Lens
B
Fig.3-
Side View
Fig.4-
Holder
2
Holder
2