2) Hybrid Flex Inverter System, error codes
Indoor units lamps,
Indoor unit
flashing of operation
and timer lamps.
and continuous
flashing of economy
lamp.
Wired remote
LCD, 7-segment
control
display
Outdoor unit
Four 7-segment lamps
on PCB
Branch box
Four lamps on PCB
2-1-3 Response procedure at error code display
Case1 : End user
Occurrence of an error
Indoor unit lamp is flashing.
Inform object person of
the number of flashing.
Error code display
Defective component
- Indoor unit error
- Abnormal units
- Outdoor unit error
- Abnormal units
- Branch box error,
Case2 : Service Engineer
except indoor units
except outdoor units
(Indoor unit, Branch-
box)
*No exception
Site visit
Check outdoor ‚7-seg
to find defectives
Indoor unit error
(7-seg : E5U1)
Branch box error
(7-seg : EJ2U)
Outdoor unit error
02-02
Appearance
Object person
OPERATION (Green)
TIMER (Orange)
ECONOMY (Green)
- End user
- Installer
- Service
LED981
LED982
POWER
ERROR
/ MODE
LED961
LED962
- Service
MODE /
SELECT
ENTER
CHECK
EXIT
- Installer
SW931
SW932
SW933
SW934
LED401
LED402
LED403
LED404
LED405
Amount of errors
Check indoor unit,
Branch Box
Check indoor unit,
Branch Box
engineer
engineer