D Auto Operation - Mitsubishi SRK10CRV-S Technical Manual & Parts List

Wall mounted type residential air-conditioners
Table of Contents

Advertisement

1.4.6 3D auto operation

(6) 3D auto operation (only CRS models)
Control the flap and louver by 3D AUTO button on the wireless remote control.
Fan speed and air flow direction are automatically controlled, allowing the entire room to efficiently conditioned.
(a) Detail of operation
(i) Perform STEP1 → STEP2 → STEP3 → STEP4 one time.
(ii) After performing STEP4 in (i) above, the next steps to be carried out are determined by the difference between
the room temperature and the setting temperature.
1) Room temperature – Setting temperature > 5ºC: STEP2
2) Room temperature – Setting temperature < 5ºC: STEP3
Operation step
Fan speed
Flap
Louver
Conditions for
jumping to next STEP
(only SRK10CJV-2, 13CJV-2)
STEP1
Auto : HIGH POWER
Setting fan speed
Other than Auto: Setting fan speed
Left louver
Right louver
The left louver and right louver
The left louver and right louver
operate in opposite directions to
operate in the same direction
each other on the left and right sides.
left and right.
_
STEP3 →
→ STEP4 are performed.
=
STEP2
Left louver
Right louver
The left louver and right louver operate in opposite directions to
each other on the left and right sides.
20 cycle

-
-
'15 • SRK-T-172
STEP4 are performed.
STEP3
STEP4
Setting fan speed
Left louver
Right louver
60 cycle
60 cycle