5. Operation
5.5. Airfl ow direction setting
<[Manual] To Change the Airfl ow's Up/Down Direction>
* The Airfl ow Up/Down button 6 cannot be used.
PSA-RP•KA
Hold both ends of the vanes and move them to the desired position. Nor-
mally, set the vanes to the horizontal or upward airfl ow direction for cool-
ing or drying mode, and set the vanes to the downward airfl ow direction
for heating mode.
* When the airflow direction is adjusted, the
uppermost and lowermost vanes do not move
together with the other vanes.
<To Change the Right/Left Air Direction>
Press the louver button 7 as necessary.
• The louver image 7 appears.
Each press of the button switches the setting as follows.
(ON)
(OFF)
Wired remote
controller
No display
During swing operation, the arrow display
(Stop)
move to the left and right.
Wireless remote
controller
No display
During swing operation, the arrow display
(Stop)
move to the left and right.
Caution:
To prevent falls, maintain a stable footing when operating the unit.

6. Timer

6.1. For Wired Remote-controller
You can use Function Selection of remote controller to select which of
3 types of timer to use: 1 Weekly timer, 2 Simple timer, or 3 Auto Off
timer.
6.1.1. Weekly Timer
The weekly timer can be used to set up to 8 operations for each day
of the week.
• Each operation may consist of any of the following: ON/OFF time
together with a temperature setting, or ON/OFF time only, or tem-
perature setting only.
• When the current time reaches a time set at this timer, the air condi-
tioner carries out the action set by the timer.
Time setting resolution for this timer is 1 minute.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2. The weekly timer will not operate when any of the following conditions is
in effect.
The timer feature is off; the system is in an malfunction state; a test run
is in progress; the remote controller is undergoing self-check or remote
controller check; the user is in the process of setting a function; the user
is in the process of setting the timer; the user is in the process of setting
the current day of the week or time; the system is under central control.
(Specifi cally, the system will not carry out operations (unit on, unit off or
temperature setting) that are prohibited during these conditions.)
5.6. Ventilation
For LOSSNAY combination
5.6.1. For Wired Remote-controller
To run the ventilator together with the indoor unit:
Press the ON/OFF button 1.
• The Vent indication appears on the screen (at 8). The ventilator
will now automatically operate whenever the indoor unit is running.
To run the ventilator only when the indoor unit is off:
Press the Mode button 2 until
will cause the ventilator to start.
To change the ventilator force:
Press the Ventilation button 8 as necessary.
• Each press toggles the setting as shown below.
(Low)
(High)
Note:
With some model confi gurations, the fan on the indoor unit may
come on even when you set the ventilator to run independently.
Operation No.
Day Setting
4
2
3
SUN
C
TEMP.
MENU
ON/OFF
BACK
MONITOR/SET
DAY
PAR-21MAA
CLOCK
OPERATION
1 9
2
<How to Set the Weekly Timer>
1. Be sure that you are at a standard control screen, and that the weekly
timer indicator 1 is shown in the display.
appears on the display. This
ON
1
WEEKLY
3
ON/OFF
1
2
4
FILTER
CHECK
TEST
0
CLEAR
78
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psa-rp100kaPsa-rp125kaPsa-rp140ka

Table of Contents