DATA

7

7-1. PERFORMANCE DATA

1) COOLING CAPACITY

MUZ-GE09NA
MUZ-GE12NA
MUZ-GE09NA2
MUZ-GE12NA2
MUZ-GE09NAH
MUZ-GE12NAH
MUZ-GE09NAH2 MUZ-GE12NAH2 MUZ-GE15NAH2
MUY-GE09NA
MUY-GE12NA
MUY-GE09NA2
MUY-GE12NA2
Indoor air
Model
IWB (˚F)
MUZ-GE09NA/NA2
MUZ-GE09NAH/NAH2
MUY-GE09NA/NA2
MUZ-GE12NA/NA2
MUZ-GE12NAH/NAH2
MUY-GE12NA/NA2
MUZ-GE15NA/NA2
MUZ-GE15NAH/NAH2
MUY-GE15NA/NA2
MUZ-GE18NA
MUZ-GE18NAH
MUY-GE18NA
MUZ-GE24NA
MUY-GE24NA
NOTE: 1. IWB: Intake air wet-bulb temperature
TC:
Total Capacity (×10
SHC: Sensible Heat Capacity (×10
TPC: Total Power Consumption (kW)
2. SHC is based on 80˚F of indoor Intake air DB temperature.

2) COOLING CAPACITY CORRECTIONS

Refrigerant piping length (one way: ft.)
MUZ-GE09NA/NA2
MUZ-GE09NAH/NAH2
MUY-GE09NA/NA2
MUZ-GE12NA/NA2
MUZ-GE12NAH/NAH2
MUY-GE12NA/NA2
MUZ-GE15NA/NA2
MUZ-GE15NAH/NAH2
MUY-GE15NA/NA2
MUZ-GE18NA
MUZ-GE18NAH
MUY-GE18NA
MUZ-GE24NA
MUY-GE24NA
OBH549F
MUZ-GE15NA
MUZ-GE15NA2
MUZ-GE15NAH
MUY-GE15NA
MUY-GE15NA2
75
TC SHC TPC
71
11.0
7.6
0.59 10.3
67
10.4
8.6
0.55
63
9.8
9.4
0.53
71
14.7
8.9
0.85 13.7
67
13.9 10.3 0.81 13.0
63
13.1 11.4 0.77 12.1 10.6 0.85 11.3
71
17.2 11.4 0.96 16.0 10.7 1.05 15.1 10.0 1.13 14.0
67
16.2 13.0 0.91 15.1 12.1 1.00 14.0 11.2 1.08 13.0 10.4 1.14 12.0
63
15.3 14.2 0.86 14.1 13.2 0.96 13.2 12.3 1.03 12.0 11.2 1.10 10.9 10.2 1.14
71
21.1 12.2 1.46 19.7 11.4 1.60 18.5 10.7 1.72 17.2
67
20.0 14.2 1.38 18.6 13.2 1.52 17.2 12.2 1.64 16.0 11.4 1.74 14.7 10.4 1.82
63
18.7 15.8 1.31 17.4 14.7 1.45 16.2 13.6 1.57 14.7 12.4 1.67 13.4 11.3 1.74
71
27.6 17.0 1.60 25.8 15.9 1.76 24.2 14.9 1.89 22.5 13.9 1.99 20.7 12.8 2.07
67
26.1 19.6 1.51 24.3 18.2 1.67 22.5 16.9 1.80 20.9 15.7 1.91 19.2 14.4 2.00
63
24.5 21.7 1.44 22.7 20.1 1.59 21.2 18.7 1.72 19.2 17.0 1.84 17.6 15.5 1.91
3
Btu/h)
3
Btu/h)
25 (std.)
40
1.0
0.954
1.0
0.954
MUZ-GE18NA
MUZ-GE18NAH
MUY-GE18NA
Outdoor intake air DB temperature (˚F)
85
95
TC SHC TPC
TC SHC TPC
7.1
0.64
9.7
6.6
9.7
8.0
0.61
9.0
7.4
9.1
8.7
0.58
8.5
8.1
8.3
0.94 12.9
7.8
9.6
0.89 12.0
8.9
9.9
65
100
0.878
0.878
0.771
28
MUZ-GE24NA
MUY-GE24NA
105
TC SHC TPC
TC SHC TPC
0.69
9.0
6.2
0.73
8.3
0.66
8.4
6.9
0.70
7.7
0.63
7.7
7.3
0.67
7.0
1.01 12.0
7.3
1.06 11.0
0.96 11.2
8.3
1.02 10.3
0.92 10.3
9.0
0.98
9.4
9.3
1.19 12.9
9.9
1.81 15.8
115
5.7
0.76
6.3
0.73
6.7
0.70
6.7
1.10
7.6
1.07
8.2
1.02
8.6
1.24
9.6
1.20
9.1
1.89