Checking before use

Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the
Mode
Indoor temperature
Cooling
16˚C~32˚C
Dry
18˚C~32˚C
Heating
27˚C or less
If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of
Maintaining your air conditioner
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type
Against cold air
De-ice cycle
Protect compressor
• If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may
have deposited at low temperatures.
6
Outdoor temperature
15˚C~52˚C
15˚C~52˚C
-5˚C~24˚C
The air conditioner does not start operating immediately to protect the compressor of
the outdoor unit after it has been started.
Indoor humidity
Relative humidity 80% or less
-
-