9-1. COOL (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button. OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with the OPERATION SELECT button.
(3) Press TEMPERATURE buttons (TOO WARM or TOO COOL button)to select the desired temperature.
The setting range is 16 ~ 31°C
1. Indoor fan speed control
Indoor fan operates continuously at the set speed by FAN SPEED CONTROL button regardless
of thermostat's OFF-ON.
In Auto the fan speed is as follows.
Room temperature minus set temperature : 2 degrees or more································High
Room temperature minus set temperature : Between 1 and 2 degrees····················Med.
Room temperature minus set temperature : less than 1 degree································Low
2. Coil frost prevention
Temperature control
When the indoor coil thermistor RT12 reads 4°C or below(MSC-C07/C09TV) / 0°C or below(MSC-C12TV) for 5 min-
utes, the coil frost prevention mode starts.
The indoor fan operates at the set speed and the compressor stops for 5 minutes.
After that, if RT12 still reads below 4°C (MSC-C07/C09TV) / 0°C (MSC-C12TV), this mode is prolonged until the
RT12 reads over 4°C (MSC-C07/C09TV) / 0°C (MSC-C12TV).
Time control
When the three conditions as follows have been satisfied for 1 hour and 45 minutes, the compressor stops for 3 min-
utes. The indoor fan operates at the set speed.
a. Compressor has been continuously operating.
b. Indoor fan speed is Low or Med..
c. Room temperature is below 26°C.
When compressor stops, the accumulated time is cancelled. When compressor restarts, time counting starts
from the beginning.
Time counting also stops temporarily when the indoor fan speed becomes High or the room temperature exceeds
26°C. However, when two of the above conditions (b.and c.) are satisfied again, time accumulation is resumed.
Operation chart
Example
OFF
Compressor
Outdoor fan
ON
Indoor fan
9-2. DRY (
) OPERATION
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a
beep tone.
(2) Select DRY mode with the OPERATION SELECT button.
(3) The microprocessor reads the room temperature and determines
the set temperature. Set temperature is as shown on the right
chart.
DRY operation will not function when the room temperature is 13°C
or below.
Initial temperature difference
ON
( continuously at set speed)
ON
OFF
Set temperature and
:
initial room temperature in dry mode
35
30
25
20
15
10
10
36
Difference between room
temperature and set tem-
Fan speed
perature during operation
1 deg. 1.7 deg.
15
20
25
30
Initial room temperature
3 deg.
35
: