Descripti on
This Submersible Sump Pump is designed for
home sumps. The permanent split capacitor
motor is oil filled, sealed for cooler running,
and has automatic-reset thermal protection.
Ball bearings on the motor shaft never need
lubrication. The power cord is a 3-wire,
grounding-type cord.

Specifications

Power supply ...................... 115V, 60 HZ., 15 Amp Circuit
Liquid Temp. Range ......................... 32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ............15 Amps
Discharge: ............................................1-1/2" Female NPT
This pump is designed for use in a residential
sump only. Pump water only with this pump.
NOTICE : This unit is not designed as a waterfall
or fountain pump, or for applications involving
salt water or brine! Use with waterfalls,
fountains, salt water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming
pool drainer.
NOTICE : Read this Owner's Manual for
installation, operation, and safety information.

General Safety Information

Your automatic sump pump should give years
of trouble-free service when correctly installed,
maintained, and used. However, interruption
of power to the pump, dirt/debris in the sump,
flooding that exceeds the pump's capacity,
electrical or mechanical failure in the pump,
etc., may prevent normal pump operation. To
help prevent damage from flooding, purchase
a secondary AC sump pump, a DC backup
sump pump, and/or a high water alarm. See
Troubleshooting in this manual for information
about common sump pump problems and
remedies. For more information,call Flotec
customer service at 1-800-365-6832 or visit our
website at FlotecWater.com.
Hazardous voltage. To reduce the risk
of hazardous or fatal electrical shock, follow
instructions A through D, below:
A. This pump has an approved 3-conductor
power cord with 3-prong, grounding-type plug.
Connect the pump only to a properly grounded,
3-prong outlet. If the sump pump circuit has
a 2-prong outlet, replace it with a grounded
3-prong outlet installed according to code.
B. Unplug the pump before handling or servicing
it. If your basement floor is wet, turn off all
power before walking on it. If the shut-off box
is in the basement, call your electric company
or hydro authority to shut off service to the
house, or call your local fire department
for instructions. After turning off the power,
remove the pump for service.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
C. Protect the electrical cords from sharp objects,
hot surfaces, oil, and chemicals. Avoid kinking
the cords. Replace damaged or worn cords.
D. Do not lift the pump by the power cord.
Fire hazard. Plastic pipe glue
is extremely flammable. Follow the glue
manufacturer's instructions when assembling
glued plastic pipe.
Burn hazard. Modern motors may run
hot. Allow 20 minutes to cool before handling.
1. Know the pump application, limitations, and
potential hazards.
2. Do not use this pump in water with
fish present.
3. Drain the system completely before
servicing it.
4. To prevent a flexible discharge line from
whipping, which could cause injury or
damage, fasten it down before starting
the pump.
5. Before each use, check any hoses in the system
for weakness or wear. Make certain that all
connections are tight.
6. Periodically inspect the sump, the pump,
and the piping for debris and foreign objects.
Perform routine cleaning as required.
7. Personal Safety:
a. Wear safety glasses at all times when
working with pumps.
b. Keep your work area clean, uncluttered
and properly lighted; put away all unused
tools and equipment.
c. Keep visitors at a safe distance from the
work area.
d. Make workshop child-proof with padlocks
and master switches. Remove any
starter keys.
8. This pump installation must meet all applicable
laws, codes, and ordinances.
Tools Required:
Pipe wrench, Strap Wrench, or Slip-Joint Pliers,
Hacksaw,
Screw Driver,
File or Sandpaper
Materials Required:
1-1/2" ABS or PVC Pipe with Cement to match
Threaded Adapter (Pipe to Pump)
Check Valve – Purchase an FP0026-10 (goes in
the discharge line) or FP0026-6D (goes in the
pump discharge). If your check valve does not
have an 1/8" anti-airlock hole, drill one in the
discharge pipe just below the check valve. Be
sure to install the check valve so that the flow
will be away from the pump.