3. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19, 1A, 1B, 1C
Specified Value 1
15 to 19
Specified Value 2
85 to 89
Specified Value 3
85 to 89
Specified Value 4
15 to 19
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
94
17
3
6
95
87
4
6
01
6D
5
6
02
6
6
01
00
Note2: The adjustment data will be automatically input to page: F, address:
17 to 1C.
Checking method:
Order Page Address Data
1
6
04
03
2
6
01
01
3
1
4
6
01
03
5
1
6
6
01
69
7
1
8
6
01
6B
9
1
IRIS display data
ND display data
Procedure
Set the data.
Set the data.
Set the data.
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note2)
Set the data, and press PAUSE
button.
Procedure
Set the data.
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Set the data, and press PAUSE
button.
Check that the ND display data
(Note1) satisfies the specified
value 3.
Set the data, and press PAUSE
button.
Check that the ND display data
(Note1) satisfies the specified
value 4.
Processing after Completing Adjustments:
Order Page Address Data
1
6
94
2
6
95
3
6
01
4
6
04
5
0
01
5-16
Ver 1.1 2000. 10
Procedure
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.