11.2.5 Connect the Cable to the Outdoor Unit

(FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT)
1
Remove the control board cover from the unit by loosening the screw.
2
Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible
cable (see below table), type designation 60245 IEC 57 or heavier cable.
3
Secure the cable onto the control board with the holder (clamper).
4
Attach the control board cover back to the original position with screw.
WARNING
This equipment must be properly earthed.
Models
UX09*E5*/UX12*E5*/
UD12*E5*/UD16*E5*
Terminals on the indoor unit
Colour of wires
Terminals on the outdoor unit
Models
UX09*E8*, UX12*E8*,
UX16*E8*, UD09*E8*,
UD12*E8*, UD16*E8*
Terminals on the indoor unit
Colour of wires
Terminals on the outdoor unit
For three phase model never operate the unit by pressing the
electromagnetic switch.
Never correct the phase by switching over any of the wires inside
the unit.
11.2.5.1
Wire Stripping and Connecting Requirement
Wire stripping
No loose strand when insert

11.2.6 Pipe Insulation

1
Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.
2
If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E FOAM with thickness 6 mm or above.
Flexible cable specification
4 x min 4.0 mm
2
1
2
3
1
2
3
Earth Wire
must be
longer than
others cables
for safety
reason.
Flexible cable specification
6 x min 1.5 mm
2
1
2
3
4
5
1
2
3
4
5
Earth Wire
must be
longer than
others cables
for safety
reason.
CAUTION
Indoor/outdoor
connecting terminal
board
5 mm or more
(gap between wires)
Select required direction and apply protective bushing
provided in accessories to protect cables from sharp edges.
Once all wiring work has been completed, tie the cable and
cord together with the binding strap so that they do not touch
other parts such as the compressor and bare copper pipes.
Outdoor Unit
Apply cut
DETAIL OF CONNECTING CABLE GUIDING
Conductor fully
insert
ACCEPT
63
Indoor/outdoor unit
terminal board
Cord clamp
Banding strap
(Field Supply)
Connecting cable
(refer below
diagram for its
guiding)
Protective
bushing 3
Selection
of direction
Conductor not
Conductor over
insert
fully insert
PROHIBITED
PROHIBITED