Wiring Schematic Diagram - Panasonic VL-SVN511 series Installation Manual

Video intercom system/main monitor station
Hide thumbs Also See for VL-SVN511 series:
Table of Contents

Advertisement

Wiring schematic diagram

Set up correctly according to the following wiring schematic diagram and "Wire type and length".
R For information, such as order numbers, about optional devices that can be connected to, refer to the
"Additional/replacement accessories" section in the Operating Instructions.
MAIN MONITOR
D1
D2
D3
D4
R1
R2
R3
IN1
IN2
IN3
10
IN4
11
P1
12
P2
13
220-240 V AC *2
C
*3
24 V DC
POWER SUPPLY UNIT
A Power supply
*1 VL-MVN511 models: The doorphone is optional (not included).
*2 VL-MVN511 models only
*3 VL-SVN511 models: Use only the supplied AC cable.
*4 VL-MVN511 models: The relay box is optional (not included).
*5 When you use an additional doorphone, the maximum number of the electric locks that can be
connected to the doorphone depends on the type of doorphone. Consult your dealer for further
information.
For VL-V554 users:
– Make sure to only connect electric vehicle gate locks to the S3/S4 terminals of the doorphones.
– Make sure to only connect electric door locks to the S1/S2 terminals of the doorphones.
DOORPHONE 1 *1,*5
NP
1
2
3
4
5
6
7
8
9
Connection device for option
Input (A contact)
B
G
NP
NP
Terminal box
(4-conductor
wiring)
DOORPHONE 2
NP
A
D
*4
RELAY BOX
F
*1,*5
You can also connect an
optional lobby station for
apartment complexes.
("Connecting an optional lobby
station" see page 7.)
E
NP
12 V AC/DC
A
NP
12 V AC/DC
A
NP: Non-polarised
PBX
Electric lock
Electric lock
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents