Wiring Diagram - Mitsubishi PKA-RP60KAL.TH Servise Manual

Table of Contents

Advertisement

7

WIRING DIAGRAM

PKA-RP60KAL.TH
PKA-RP60KAL.TH-ER
PKA-RP60KALR1.TH
PKA-RP60KALR1.TH-ER
[LEGEND]
SYMBOL
I.B
Indoor controller board
CN2L
Connector (LOSSNAY)
CN32
Connector (Remote switch)
CN41
Connector (HA terminal-A)
CN51
Connector (Centrally control)
CN90
Connector (Remote operation adapter)
DSA
Surge absorber
FUSE
FUSE (T3.15AL250V)
LED1
Power supply (I.B)
LED2
Power supply (R.B)
LED3
Transmission (Indoor-outdoor)
SW1
Switch (Model selection) wSee table 1
SW2
Switch (Capacity code) wSee table 2
SWE
Connector (Emergency operation)
X1
Relay (Drain pump(option))
ZNR01,02
Varistor
CNP
Drain pump (option) power supply
(Sold separately:Drain pump(option))
CN4F
Drain float switch (Sold separately:Drain pump (option))
R.B
Wired remote controller (option)
TB6
Terminal block (Remote controller transmission line)
The black square (
) indicates a switch position.
Notes:
1. SymboIs used in wiring diagram above are,
2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers
(S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric
wiring diagram for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting wires.(specification of 230V),
adopting superimposed system of power and signal.
w1 When work to Supply power separately to indoor and outdoor units was applied,refer to Fig 1.
w2 For power supply system of this unit, refer to the caution label located near this diagram.
OCH452B
PKA-RP71KAL.TH
PKA-RP71KAL.TH-ER
PKA-RP71KALR1.TH
PKA-RP71KALR1.TH-ER
NAME
SYMBOL
M
MS
S.W
SWE2
TB2
TB4
TB5
TH1
TH2
TH5
W.B
LED1
LED2
REC1
DCL
DP
FS
MF
:Connector,
PKA-RP100KAL.TH
PKA-RP100KAL.TH-ER
PKA-RP100KALR1.TH
PKA-RP100KALR1.TH-ER
NAME
Vane motor
Fan motor
Switch board
Emergency operation
Terminal block (Indoor unit Power (option))
Terminal block (Indoor/outdoor connecting line (option))
Terminal block (Remote controller transmission line)
Room temp. Thermistor
(0: / 15k", 25: / 5. 4k" Detect)
Pipe temp. Thermistor/liquid
(0: / 15k", 25: / 5. 4k" Detect)
Cond. / eva. temp. Thermistor
(0: / 15k", 25: / 5. 4k" Detect)
PCB for wireless remote controller
LED (Operation indication : Green)
LED (Preparation for heating : Orange)
Receiving unit
REACTOR
DRAIN PUMP (OPTION)
DRAIN FLOAT SWITCH (OPTION)
w1(Fig. 1)
CN01
(BLK)
1
3
5
I.B
1
CN3C (BLU)
: Terminal (block).
9
I.B
TB2
YLW
RED
L
POWER SUPPLY
ORN
BLU
~(1PHASE)
N
GRN/YLW
230V 50Hz
TB4
YLW
S1
ORN
TO OUTDOOR
ORN
S2
BRN
UNIT
S3
INDOOR/OUTDOOR
3
COMMUNICATION

Hide quick links: