Panasonic CS-E9HKEA Service Manual page 7

Hide thumbs Also See for CS-E9HKEA:
Table of Contents

Advertisement

ITEM
Fin Material
Fin Type
Heat Exchanger
Row x Stage x FPI
Size (W x H x L)
Material
Air Filter
Type
1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air
temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.)
2. Heating capacities are based on indoor temperature of 20qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF
D.B.), 6qC W.B. (42.8qF W.B.)
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Starting Current
Running Current
Power Factor
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
Number of core
Power Cord
Length
Thermostat
Protection Device
Note
• Specifications are subject to change without notice for further improvement.
UNIT
INDOOR UNIT
Aluminium (Pre Coat)
Slit Fin
2 x 15 x 21
mm
610 x 315 x 25.4
P.P. Honey Comb
One-Touch
Unit
ø
V
Hz
W
A
A
%
A
m
7
OUTDOOR UNIT
Aluminium
Corrugated Fin
2 x 24 x 17
36.4 x 504 x 713
Single
230
50
Cooling; 920 (120 ~ 1180)
Heating; 1260 (115 ~ 1850)
5.8
Cooling; 4.3
Heating; 5.8
Cooling; 93
Heating; 94
8.4
2
3 (1.5 mm
)
1.8
Electronic Control
Electronic Control
684

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-e9hkeaCs-e12hkeaCu-e12hkea