Hydro Unit And Outdoor Unit Settings - Toshiba HWS-803XWHM3-E Service Manual

Hide thumbs Also See for HWS-803XWHM3-E:
Table of Contents

Advertisement

10

Hydro unit and Outdoor Unit Settings

Hydro unit
1. Hydro unit Setting
1-1. Setting switch names and positions
1-2. SW02 (System switching 1)
SW02
Boiler install position After 3WV heating side/Before 3WV
02_1
02_2
02_3
02_4
Room thermostat
1-3. SW10 (Pump switching)
SW10
Pump P1 operation during hot water mode
10_1
OFF = P1 ON during heat pump activate
ON = P1 Continues run
Pump P1 operation during room heating. P1 pump stop or
not using out side air temperature.
10_2
OFF = Continues run
ON = Pump P1 stop when TO>20
the temperature setting by FC 9E)
10_3
Pump P2 interlock with P1 Yes/No
10_4
1-4. SW11 (Heater Yes/No switching)
SW11
11_1
Hydro unit backup heater Energized Yes/No
11_2
Hot water cylinder heater Energized Yes/No
11_3
External booster heater output Enabled Yes/No
11_4
1-5. SW12 (System switching 2)
SW12
12_1
Hot water supply
12_2
ZONE1
12_3
ZONE2
12_4
SW01
SW02
SW10
Switching details
Switching details
o
C (Available to change
Switching details
Switching details
127
SW12
SW13
SW11
SW07
SW06
Factory default
After 3WV,
OFF
heating
OFF
OFF
No
OFF
Factory default
Heat-pump
OFF
activate
Continuous run
OFF
Yes
OFF
OFF
Factory default
Energised
OFF
Energised
OFF
Enabled
OFF
OFF
Factory default
Yes
OFF
Yes
OFF
No
OFF
OFF
Remarks
Before 3 WV
Remarks
Remarks
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents