Function Indicator Symbols - Philips DVP620VR/78 Service Manual

Hide thumbs Also See for DVP620VR/78:
Table of Contents

Advertisement

Note:
If a mechanical malfunction occurs, the power is turned off. When the power comes on again after that by
pressing [STANDBY-ON] button, an error message is displayed on the TV screen for 5 seconds.
Led Mode
When reel and capstan mechanism is not
functioning correctly
When tape loading mechanism is not func-
tioning correctly
When cassette loading mechanism is not
functioning correctly
When the drum is not working properly
TV screen
When reel and capstan mechanism is not functioning
correctly
EJECT A R
When tape loading mechanism is not functioning cor-
rectly
EJECT A T

FUNCTION INDICATOR SYMBOLS

"EJECT A R" is displayed on a TV screen. (Refer to Fig. 1.)
"EJECT A T" is displayed on a TV screen. (Refer to Fig. 2.)
"EJECT A C" is displayed on a TV screen. (Refer to Fig. 3.)
"EJECT A D" is displayed on a TV screen. (Refer to Fig. 4.)
Fig. 1
Fig. 2
Indicator Active
When cassette loading mechanism is not functioning
correctly
EJECT A C
When the drum is not working properly
EJECT A D
1-4-1
Fig. 3
Fig. 4
H9622FIS