Lennox ML193UH045P36B Unit Information page 9

Ml193uh series
Hide thumbs Also See for ML193UH045P36B:
Table of Contents

Advertisement

The integrated control is equipped with two LED lights for troubleshooting. The diagnostic codes are listed below in table 3.
LED #1 (Red)
LED #2 (Green)
SIMULTANEOUS
SLOW FLASH
SIMULTANEOUS
FAST FLASH
SLOW FLASH
OFF
ALTERNATING
SLOW FLASH
SLOW FLASH
ON
ON
ON
OFF
FAST FLASH
SLOW FLASH
ALTERNATING
FAST FLASH
NOTE - Slow flash rate equals 1 Hz (one flash per second). Fast flash rate equals 3 Hz (three flashes per second).
Minimum flame sense current = 0.5 microAmps.
É É
Pre -Purge
ON
É É
É É
OFF
É É
É É É É É É É É É É É É É É É É É É É É É É É É
DEMAND
CAI
É É É É É É É É É É É É É É É É É É É É É É É É É É
É É É É É É É É É É É É É É É É É É É É É É É É
IGNITOR
GAS VALVE
INDOOR BLOWER
*Ignitor will energize the first 3 seconds of the 4 second trial for ignition
**Blower on time will be 45 seconds after gas valve is energized. Blower off time will depend on "OFF TIME" Setting.
TABLE 3
DIAGNOSTIC CODES
Make sure to Identify LED'S Correctly.
Power on - Normal operation.
SIMULTANEOUS
Also signaled during cooling and continuous fan.
SLOW FLASH
SIMULTANEOUS
Normal operation - signaled when heating demand initiated at thermostat.
FAST FLASH
Primary or secondary limit switch open. Limit must close within 3 minutes or unit
ON
goes into 1 hour Watchguard.
Pressure prove switch open.
SLOW FLASH
OR: Blocked inlet/exhaust vent;
OR: Pressure switch closed prior to activation of combustion air inducer.
Watchguard 1 hour -- burners failed to ignite or lost flame 5 times during single
ALTERNATING
heating demand.
SLOW FLASH
OFF
Flame sensed without gas valve energized.
SLOW FLASH
Rollout switch open. OR: 12‐pin connector improperly attached.
ON
Circuit control failure or control wired incorrectly.
OFF
ON
SLOW FLASH
Main power polarity reversed. Switch line and neutral.
FAST FLASH
Low flame signal. Measures below 1.5 microamps. Replace flame sense rod.
Improper main ground.
ALTERNATING
OR: Line voltage below 90 volts.
FAST FLASH
15 Sec.
20 sec.
Ignitor Warmup
É É É É É É É É É
É É É É É É É É É
DESCRIPTION
*4
**Blower "On"
Sec.Trial
Delay
for Ign.
É É É É É É É É É É É É É
FIGURE 5
Page 9
End of
5 SEC
Heat Demand
Blower
Post
Purge
É É É É É É É É É
É É É É É É É É É
Off
Time