Follow These Steps When Battery Is Outside Vehicle; Grounding And Ac Power Cord Connections; Assembly Instructions; Control Panel - DieHard 28.71341 Operator's Manual

6v/12v automatic battery charger & engine starter
Table of Contents

Advertisement

7. FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE

A SPARK NEAR THE BATTERY MAY
CAUSE A BATTERY EXPLOSION. TO
REDUCE THE RISK OF A SPARK NEAR
THE BATTERY:
7.1 Check polarity of battery posts. POSITIVE
(POS, P, +) battery post usually has a larger
diameter than NEGATIVE (NEG, N, –) post.
7.2 Attach at least a 24-inch-long 6-gauge
(AWG) insulated battery cable to
NEGATIVE (NEG, N, –) battery post.
7.3 Connect POSITIVE (RED) charger clip to
POSITIVE (POS, P, +) post of battery.
7.4 Position yourself and free end of cable as
far away from battery as possible – then

8. GROUNDING AND AC POWER CORD CONNECTIONS

This battery charger is for use on a nominal
120 volt circuit and has a grounded plug.
The charger must be grounded, to reduce
the risk of electric shock. The plug must
be plugged into an outlet that is properly
installed and grounded in accordance with
all local codes and ordinances. The plug
pins must fit the receptacle (outlet). Do not
use with an ungrounded system.
DANGER: Never alter the AC cord or
plug provided – if it does not fit the outlet,
have a proper grounded outlet installed
by a qualified electrician. An improper
connection can result in a risk of an
electric shock or electrocution.
NOTE: Pursuant to Canadian
Regulations, use of an adapter plug
is not allowed in Canada. Use of an
adapter plug in the United States is not
recommended and should not be used.

9. ASSEMBLY INSTRUCTIONS

9.1 Remove all cord wraps and uncoil the
cables prior to using the battery charger.

10. CONTROL PANEL

ON/OFF SWITCH
Use this switch to select between the
Charge/Maintain rate, Boost rate and the
Engine Start mode.
• OFF – When the switch is in this position
(middle), the charger is turned off.
• BOOST or CHARGE/MAINTAIN –
When the switch is in this position, the
Rate Selection button can be set to either
the 6<>2A Charge/Maintain or the
50A Boost setting.
• ENGINE START – When the switch is
in this position, the Engine Start LED will
illuminate.
connect NEGATIVE (BLACK) charger clip
to free end of cable.
7.5 Do not face battery when making final
connection.
7.6 When disconnecting charger, always do
so in reverse sequence of connecting
procedure and break first connection
while as far away from battery as
practical.
7.7 A marine (boat) battery must be removed
and charged on shore. To charge it on
board requires equipment specially
designed for marine use.
USING AN EXTENSION CORD
The use of an extension cord is not
recommended. If you must use an
extension cord, follow these guidelines:
• Pins on plug of extension cord must be
the same number, size, and shape as
those of plug on charger.
• Ensure that the extension cord is
properly wired and in good electrical
condition.
• Wire size must be large enough for
the AC ampere rating of charger, as
specified:
Length of cord (feet)
AWG* size of cord
*AWG-American Wire Gauge
9.2 Extend the handle from the retracted
position by pulling it upward until it locks
into place. (Press the small silver buttons
inward, if necessary.)
DIGITAL DISPLAY
The Digital Display gives a digital
indication of voltage, % of charge or
time. The display will show the battery
VOLTAGE when the charger is not
charging a battery. When it goes
into charging mode, the display will
automatically change to ON (to show
charging has started) and either 6 or 12
(the voltage of the battery, determined
by the charger). If you manually stop the
charging process (by pressing the Rate
Selection button) before the battery is fully
charged, the display will show Off.
• 6 •
25
50
100
150
14
12
10
8

Advertisement

Table of Contents
loading

Table of Contents