SETUp & TESTINg
SYSTEm SETUp INSTRUCTIONS
System setting
16 Low Balance Pt. (8446, 8448HP, 8465, 8466HP)
17 High Balance Pt. (8446, 8448HP, 8465, 8466HP)
19 Program format (8463, 8465, 8366)
20 Change air filter
21 C hange water panel
*Set number of months until reminder is required
22 Humidifier type
23 Service dehumidifier
24 Service HVAC
61000652A 8400 Tstat Install.indd 15
(CONTINUED)
Setting range, default in bold
20°f (–7°C)
1°F to 35°F (–17°C to 2°C) or "OFF" to disable
60°f (16°C)
40°F to 80°F (4°C to 27°C) or "OFF " to disable
0 – 5/2 program (weekdays and weekends)
1 – 5/1/1 program (Weekdays, Sat. and Sun.)
Off
1, 3, 6, 12 months or "OFF" to disable
Off
1 to 12 months or "OFF" to disable
0 : flow through type humidifier
1 : Drain-less type humidifier
Off
1 to 12 months or "OFF" to disable
Off
1 to 12 months or "OFF" to disable
(1 reminder per season)
(2 reminders per season)