4. RGB Sensor
Abnormal RGB Sensor part
Check the Voltage
R703 = 2.8V
C703 = 2.8V
Check the Voltage
R451 = 1.8V
R452 = 1.8V
Barometer Sensor operate
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
Yes
Yes
Yes
correctly?
Yes
END
No
Resolder U703,R703 or heat over U500
No
Resolder U500 or heat over UCP400
No
change VT camera assenbly
8-43
Level 3 Repair