3. Barometer Sensor

Abnormal Barometer Sensor part
Check the Voltage
C250 = 1.8V
C246 = 1.8V
Check the Voltage
R432 = 1.8V
R433 = 1.8V
Barometer Sensor operate
correctly?
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
Yes
Yes
Yes
Yes
END
No
Resolder U206 or heat over U500
No
Resolder U500 or heat over UCP400
Apply Heat over or Replace U206 using a
No
Heatgun or change PBA