1-7-4. E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the following process.
Order Page Address Data
1
0
01
2
0
10
B
3
B2
(6B)
4
0
10
D
5
47
(7D)
D
6
49
(7D)
D
7
49
(7D)
D
8
47
(7D)
D
9
49
(7D)
D
10
49
(7D)
11
0
10
B
12
B2
(6B)
13
0
10
14
0
01
15
16
17
18
19
20
Note 1: Finish this operation within 10 seconds. If it is likely to take more than 10 seconds, set page: D (7D), address: 49, data:
00, and then retry.
Note 2: When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
1-7-5. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
1
Turn the power ON.
Check that R1823 in the periphery of IC1801 on the VC-500 board is 0 Ω and energizes. If it is not energizes, replace the R1823.
2
When R1823 is 0 Ω and energizes, replace the lens block (Note).
Check that no error occurs, after replacing the lens block and performing the necessary adjustment. If an error occurs, inspect
3
the camera control circuit (IC1801 of VC-500 board) periphery.
Note: When the lens block was replaced, execute the necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
HDR-HC9/HC9E_L2
01
06
01
Press PAUSE (Write) button.
07
F0
Press PAUSE (Write) button.
01
Press PAUSE (Write) button. (Note 1)
00
Press PAUSE (Write) button.
10
Press PAUSE (Write) button.
01
Press PAUSE (Write) button. (Note 1)
00
Press PAUSE (Write) button.
06
00
Press PAUSE (Write) button.
00
00
Check if the shift lens moves while setting the order 5 to 10. If the shift lens does not move, replace the
lens block (Note 2). When the shift lens moved, proceed to the order 16.
While setting the order 5 to 10, measure with an oscilloscope the output voltage of R5737 in the periphery
of IC5703 on the LD-221 board to check the output voltage varies.
If the output voltage does not vary, replace the lens block (Note 2). When the output voltage varied,
proceed to the order 18.
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R5792 in the periphery of IC5703 on the
LD-221 board, turn the power ON to check that the output voltage immediately after the power on
change as shown in Fig. 2.
If the output voltage change as shown in Fig. 2, replace the lens block (Note 2). If it does not change as
shown in Fig. 2, inspect the camera control circuit (IC1801 of VC-500 board) periphery.
Procedure