NoTeS
0. Install the connecting rod cap with its match mark aligned
with identical mark on rod.
. Install the connecting rod cap bolts and tighten to the
proper torque.
CYlINder ServICe
INSPECTION:
. Inspect cylinder for dirty, broken or cracked cooling fins.
2. Check cylinder wall for wear, scoring or other damage.
. Check all bearing surfaces for wear, scoring or other
damage.
REBORING THE CYLINDER:
At the time this Manual was published, oversize pistons and
rings were not available and reboring of the cylinder to an
oversize cannot be done.
*
CAuTIoN! do NoT ATTeMPT To rebore THe CYlIN-
der. overSIZe PArTS Are NoT AvAIlAble.