Pioneer XV-HTD50 Service Manual page 89

Hide thumbs Also See for XV-HTD50:
Table of Contents

Advertisement

5
QQ
Description
3 7 63 1515 0
FL
of Error
ID can not read
71
during tracing
Subcode check
72
failure during
playback
ID can not read at
73
the startup
Subcode check
74
failure during startup
Timeout for reading
81
TOC of the
mechanism
controller
Timeout for reading
82
TOC of the system
controller
Communication
A1
timeout of DSP
command
Communication
A2
timeout for reading
DSP coefficient
Communication
A3
timeout for writing
DSP coefficient
Communication
TE
L 13942296513
timeout for
A4
continuously writing
DSP coefficient
Timeout error for
B1
backup
Retry error for
B2
backup
B3 Retry error for trace
Detection of tracking
C3
overcurrent
Short-circuit test
(C5)
corresponding error
Violation against
E3
digital copy guard
F5 Tray being pushed
F8 Loading timeout
FC Focus
www
.
5
http://www.xiaoyu163.com
6
Causes if with a DVD
An ID could not be read for 1 second or more.
An ID could not be read within 1 second after the
AFB adjustment had been finished.
A command could not be issued to DSP because
Command Busy (XCBUSY) was in force
(XCBUSY = L) for a specified time (about 200
mS).
Command Busy (XCBUSY) was in force for a
specified time (about 200 mS) before and after a
coefficient read command was issued to DSP, or
the address echo-back after command issuance
did not match the setup address.
Command Busy (XCBUSY) was in force for a
specified time (about 1024 mS) before and after
the coefficient write command was issued to
DSP.
Command Busy (XCBUSY) was in force for 200
mS during continuous coefficient writing, or
before and after a continuous write command
was issued to DSP.
In the tracing state during the backup sequence, codes could not be read for 1
second or more. In the backup sequence, tracking ON sequence of the servo DSP
could not be completed even if more than 500 mS after the tracking ON command
was issued.
Tracing impossible after retring the tracking ON for 3 times in the backup sequence.
During tracing, runaway was detected after three iterations of backup operations for
detecting runaway.
During playback, the overcurrent detection port was at L for 300 ms or more
continuously.
While the power was on, the overcurrent detection port was at L for 40 ms or more
continuously.
The tray switch that had been Open mode was forcibly changed to a mode other than
Open by an external force.
Loading, unloading or clamping could not be completed within a specified time (about
5 seconds).
The following error occured eight times.
(1) Focus ON sequence could not be completed even if more than two seconds after
the focus ON command (to the servo DSP) was sent.
(2) Focus IN sequence was finished, actually focus IN was not completed.
x
ao
u163
y
i
6
http://www.xiaoyu163.com
7
2 9
8
Causes if with a CD
No frame could be read for 3
seconds or more.
No subcode could be read within 3
seconds after AFB adjustment had
been finished.
TOC readout took 30 seconds or
more.
Reading TOC of the system
controller took 30 seconds or
Q Q
3
6 7
1 3
1 5
co
.
XV-HTD50
7
9 4
2 8
Operation of the Unit
Stop
Stop
Opens (ID readout
failure)
Opens (Subcode readout
failure).
Stop
Stop
No operation
No operation
No operation
0 5
8
2 9
9 4
2 8
No operation
Stops
Stops
Stops
Stops (the mechanical
controller operates
independently).
Turns off the power
instantly (No indication on
the FL display and no
writing to flash memory)
Stops
Closes
Reverses the loading
direction. It timeout is
repeated upon retry, the
unit stops.
Stops wherever possible
m
then opens (stops in the
case of side B).
8
9 9
A
B
C
9 9
D
E
F
89