Nokia RM-632 Service Manual page 87

Table of Contents

Advertisement

RM-632; RM-634; RM-699
BB Troubleshooting and Manual Tuning Guide
Measurement data
If a special low-pass filter designed for measuring digital amplifiers is unavailable, the measurement must be performed with a
current probe and the input signal frequency must be 2kHz.
Figure 14 Differential output waveform of the Ext_in_IHF_out out loop measurement when speaker is connected.
Issue 3
COMPANY CONFIDENTIAL
Page 3 – 45