EXTERNAL OUTPUT

You can display air conditioner ON/OFF operation by external output.
Note) Only ON/OFF is output as external output. Regarding MODE, AIR FLOW RATE, SET
TEMPERATURE, error signals and others, please check the display on the main unit or the remote
controller.
[Example]
Non-voltage contact
Contact capacity: Max. 24VDC, 10mA to less than 1A
indoor unit status
external output signal
Parts (Optional)
Model name
UTY-XWZX
Wire (External output) : Blue / Purple
Indoor unit
Printed
circuit
board
EXT.
IN
1
EXT.
CN103
OUT
2
Signal Specification
OPERATION
STOP
SHORT
OPEN
Parts No.
9028651003