General information
Venting compartments
▶ Ventilation must be provided for boilers fitted into
compartments as described in BS 5410
▶ A minimum of two air vents must be fitted, one at low level
and another at high level onto the same wall using the same
air for circulation.
▶ Combustion air must not be taken from a room or internal
space containing a bath or shower and must not
communicate with a protected area such as a hall, stairway,
landing, corridor, lobby, shaft etc.
▶ Air vents must allow access for clean free air and must be
sited to comply with the flue terminal position
requirements.
▶ Air ducting runs must not exceed 3m.
▶ Low level air vents must be less than 450mm from the
floor.
▶ A warning label must be attached to the vents with a
statement to the effect:
"Do not block this vent. Do not use for storage".
5.2

General notes

To get the best from your boiler. please read these instructions
carefully.

5.2.1 Central heating systems

During the first few hours of operation of the central heating
system, check that all radiators are being heated at an even
rate. If the top of a radiator is at a lower temperature than the
bottom then it should be vented by releasing air through the
venting screw at the top of the radiator. Ask your installer to
show you how this is done. Repeated venting will reduce the
quantity of water in the system and this must be replenished for
safe and satisfactory operation of the boiler.
When excessive venting or water leaks are found in the system
you must contact a service engineer to inspect the installation
and rectify any fault.
Only use additives compatible with the boiler and system. Use
of incompatible additives can cause damage and will invalidate
the boiler guarantee.
8

5.2.2 Condensate drain

This is a condensing boiler and the terminal will, at times give
out a plume of water vapour. This is quite normal.
The boiler also produces quantities of condensate which is
discharged regularly via a pipe to drain. This pipe must not be
blocked or altered in any way.

5.2.3 Clearances - service

Your installer will have provided adequate space around the
boiler for safety and servicing access.
Do not restrict this space with the addition of cupboards,
shelves etc. next to the boiler.