Mounting Of Indoor Unit Installation Plate - LG LS091HSV3 Installation Manual

Single zone high efficiency, standard, extended pipe, and mega wall mounted
Hide thumbs Also See for LS091HSV3:
Table of Contents

Advertisement

Mounting Installation Plate to Wall (Mega 115V - HXV Models)
Follow the procedure and best practices when mounting the indoor
unit's plate to a wall.
Procedure
1. Mount the installation plate horizontally by aligning the centerline
using a leveling tool (Figure 24).
2. Use type "A" screws when mounting the plating (these screws
come with the plate).
• If mounting the unit on concrete wall, use eld supplied anchor bolts.
3. Observe the left and right rear piping clearance when drilling into
the wall, as shown in Figure 25.
Select location carefully. Unit should be anchored to a strong wall to pre-
vent unnecessary vibration.
• When choosing a location for the wall mount plate, be sure to take
into consideration routing of wiring for power outlets within the wall.
Contacting wiring can cause serious bodily injury, or death.
• Use caution when drilling holes through the walls for the purposes
of piping connections. Power wiring can cause serious bodily injury,
or death.
Figure 25: Installation Plate - Mega 115V
Installation Plate
16-
8/32
Unit Outline
Ø2-19/32
Place a level on raised tab
Left Rear
5-11/32
Piping
7
GENERAL INSTALLATION GUIDELINES
18-
29/32
4-
27/32
Unit: Inch
9-
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.

Mounting of Indoor Unit Installation Plate

Figure 24: Installation Plate - Mounting Mega 115V
Chassis
Hook
Refer to "Drilling Piping Hole in the Wall" on page 22 as
you follow procedure to install plate.
Ø2-19/32
Right Rear
Piping
21/32
Installation Plate
Type "A" Screws