Installation - Carrier 42 HWS 07 Installation Manual

Table of Contents

Advertisement

42 HWS

Installation

243
20
223
140 mm
120 mm
D mm
20
380
IMPORTANT NOTE:
This unit has no refrigerant expansion device.
Establish the direction of refrigerant tubing.
Refrigerant tubes can run in directions indicated by
For directions
,
and
, break the knockout in the side panel.
Direction
is recommended for sizes 18 and 24 only.
Mod. 07 - 09 - 12
Mod.18 - 24
Installation of the wall mounting plate.
Refer to "Minimum clearance" between unit, side walls and ceiling.
Place mounting plate against the wall, then level with a plumb line
or spirit level and mark the position of the mounting holes to be
drilled.
Wall mounting plate centre line of size 18 and 24 does not coincide
with the installed unit centre line, which is indicated with a vertical
line on the mounting plate.
Drill holes and install the plate using the 4 screw anchors and
screws provided.
Check that no vibrations can occur by movement of the plate.
GB - 6
800
314
270 mm - Ø 70
270 mm - Ø 70
270
,
,
243
223
20
140 mm
120 mm
D mm
70
110
130
,
,
.
Making the hole in the external wall for interconnecting tubes to
the outdoor unit.
Drill a 70 or 80 mm dia. hole (depending on unit size) in the
external wall using the plate or the template provided with the unit
(see " Table II, Ref.7).
The hole should have a 5-10 mm slope toward the outside. Insert
the plastic conduit provided.
Pass the electric connecting wires through the conduit (see
electrical connections).
Plate
Mod.
A
B
C
290
40
44
07
337
87
60
09 - 12
Mod. 07 - 09 - 12
Mod. 18 - 24
Indoors
Outdoors
D
60
90