4-1. Service Mode
4-1-1. Start
1. Input any signal to this unit.
2. Turn on the power of this unit.
3. Perform the operation below using a remote controller
(RM-FW001) supplied for this unit with OSD not
displayed.
(1) Press the
button two times.
(2) Press the [MUTING] button.
(3) Press the
button.
(4) Press the [MUTING] button.
(5) Press the [MENU] button.
The service mode is started.
n
To exit this screen, press the [MENU] button.
FWD-40LX2F
FWD-40LX2X
Section 4
Electrical Alignment
4-2. White Balance Adjustment
This unit is adjusted to the prescribed white balance during
factory setting. The average value of white balance is
written in the A board during factory setting. (AD calibra-
tion has also been adjusted during factory setting.)
Perform the adjustment in this section when white balance
adjustment is required.
Initial values of A board
* * * * * 1
COOL
NEUTRAL 253
WARM
*1: GAIN
*2: OFFSET
4-2-1. Preparation
Required equipment
. Signal generator
n
It is recommended to use 480i (HD15 Component) as a
connection signal. However, the signal to be actually
input can also be used.
. Color thermometer
Preparation
1. Input a signal to this unit and age for 30 minutes or
more.
4-2-2. Setting
1. Start the service mode. (Refer to Section 4-1-1.)
2. Select "HD15" by "INPUT SOURCE" in a menu.
n
Select according to the input signal when inputting any
signal.
RED
GREEN BULE RED
* * * * * 1
* * * * * 1
* * * * * 2
* * * * * 2
235
223
255
122
238
250
122
255
235
222
121
GREEN BLUE
* * * * * 2
125
124
124
125
123
125
4-1