7-3. Initial Function

A. Initial function of first POWER ON
1)
If power is pressed (POWER S/W ON), it will begin to make a self diagnosis and light all
DISPLAY for 2 seconds if normal condition is confirmed
2)
After lighting DISPLAY ON, 7-Segment will be displayed as -- .
3)
Defrosting HEATER is set to be ON forcibly for 3 seconds irrespective of the evaporator
temperature.
4)
After turning the defrosting HEATER ON for 3 seconds, turn off the defrosting HEATER and
turn COMP. ON and keep it up for 5 minute irrespective of temperature of refrigerator.
5)
After turning COMP. ON, operate DAMPER-MOTOR for control of refrigerator and confirm the
zero point and 60Hz/50Hz and then control as considering the temperature condition of refrigerator.
6)
At this moment, if it does not confirm the zero point due to the disorder of the some part of
DAMPER-MOTOR, COMP. will be stoped immediately and display self diagnosis.

7-4. Defrosting Function

A. Common function
1)
The period of defrosting is set to be 19 hours according to the COMP intergrated criterion.
Previous standard means the following conditions : frequency of opening and closing of the DOOR
of refrigerator must be less than one time, the temperature of refrigerator and the temperature of
freezer did not increase above TRSET ON+6
functional button (VAC,SUPER,ECO)was not selected. Besides the predescribed condition,
the period of defrosting will be 6 hours and 50 minutes unconditionally.
2)
If power is turned off and then is turned on again, the commencement of defrosting will be after
4 hours of the running time of compressor.
3)
The COMP and FAN during defrosting, will stop and DAMPER-MOTOR will swing continuously.
4)
At a pause time, DAMPER-MOTOR.
5)
With the exception of 19 hours in the period of defrosting, will also swing the Pre_Cooling will be
executed by operating the COMP forcibly for 50 minutes before execution of defrosting.
6)
You are recommended to have a pause time after completion of HEATING.
7)
The HEATING for defrosting will be controlled by SENSOR. If SENSOR is out of order or the temperature
of EVAP is higher than HEATER ON temperature, HEATING will be skipped and ref only has a pause time.
B. Defrosting Function while SUPER function is working
1)
The operation of defrosting while SUPER function is working will be delayed until the compressor
running time is to be 2 hours.
2)
If the SUPER function is released by pushing the button before completion of SUPER function,
the defrosting function will be operating including the worked time of COMP. operation which was
worked by SUPER function.
3)
If SUPER function is selected while defrosting function is working, DISPLAY will be set to be SUPER
ON condition immediately, but SUPER function will be working after completion of defrosting function.
C. HEATER ON/OFF during defrosting
1)
The temperature of defrosting HEATER ON
General defrosting
below -5
2)
The temperature of defrosting HEATER OFF
Section
OFF
OFF
15
and TFSET ON+4 , respectively and special
Forced defrosting
below -5
6 hours and
50 minutes
12
12
Same under all defrosting condition
19 hours
4 hours
12
12
12
12
Note
Note