Instructing The Owner; Notice To Owner; Indications Of Proper Operation; Maintenance - York E9FD018 Series Installation Instruction

Outdoor split-system heat pumps
Table of Contents

Advertisement

INSTRUCTING THE OWNER

Assist owner with processing warranty cards. Review User's
Information Manual and provide a copy for the owner guidance
on proper operation and maintenance. Instruct the owner or the
operator how to start, stop and adjust temperature setting. The
owner should also be instructed about the 5 minute off cycle
timer and the defrost operation.
When applicable, instruct the owner that the compressor is
equipped with a crankcase heater to prevent the migration of
refrigerant to the compressor during the "OFF" cycle. The
heater is energized only when the unit is not running. If the main
switch is disconnected for long periods of shut down, do not
attempt to start the unit for 8 hours after the switch has been
connected. This will allow sufficient time for all liquid refrigerant
to be driven out of the compressor.
The installer should also instruct the owner on proper operation
and maintenance of all other system components.

INDICATIONS OF PROPER OPERATION

COOLING
Cooling operation is the same as any conventional air condi-
tioning unit.
1. The outdoor fan should be running, with warm air being
discharged from the top of the unit.
2. The indoor blower (furnace or air handler) will be operating,
discharging cool air from the ducts.
3. The vapor line at the outdoor unit will feel cool to the touch.
4. The liquid line at the outdoor unit will feel warm to the touch.
HEATING
Indications of proper Heating operation is as follows:
1. The outdoor fan should be running, with cool air being
discharged from the top of the unit.
2. The indoor blower (furnace or air handler) will be operating,
discharging warm air from the ducts.
3. The vapor line at the outdoor unit will feel warm to the touch.
4. The liquid line at the outdoor unit will feel cool to the touch.
Unitary Products Group
P.O. Box 1592, York, Pennsylvania USA 17405-1592
Subject to change without notice. Printed in U.S.A.
Copyright © by York International Corporation 1996. All Rights Reserved.

NOTICE TO OWNER:

If lockout occurs, check the following before calling a serviceman:
1. Indoor section for dirty filter.
2. Outdoor section for snow accumulation.
3. Outdoor section for leaf or debris blockage.
Eliminate problem, turn off the thermostat for 10 seconds and attempt
start. Wait 5 minutes. If system does not start, call serviceman.

MAINTENANCE

1. Dirt should not be allowed to accumulate on the outdoor
coils or other parts in the air circuit. Clean as often as
necessary to keep the unit clean. Use a brush, vacuum
cleaner attachment, or other suitable means.
2. The outdoor fan motor is permanently lubricated and does
not require periodic oiling.
3. If the coil needs to be cleaned, it should be washed with
Calgon Coilclean (mix one part Coilclean to seven parts
water). Allow solution to remain on coil for 30 minutes
before rinsing with clean water. Solution should not be
permitted to come in contact with painted surfaces.
4. Refer to the furnace or air handler instructions for filter and
blower motor maintenance.
5. The indoor coil drain pan should be inspected and cleaned
regularly to prevent odors and assure proper drainage.
CAUTION: IT IS UNLAWFUL TO KNOWINGLY VENT, RE-
LEASE OR DISCHARGE REFRIGERANT INTO THE OPEN
AIR DURING REPAIR, SERVICE, MAINTENANCE OR THE
FINAL DISPOSAL OF THIS UNIT.
WHEN THE SYSTEM IS FUNCTIONING PROPERLY AND
THE OWNER HAS BEEN FULLY INSTRUCTED, SECURE
THE OWNER'S APPROVAL.
Code: SBY
SHU 12M 296 .66
515.26-N5Y