Installation of Indoor Unit

1. Hook the indoor unit onto the upper portion of the
installation plate.( engage the three hooks at the top
of the indoor unit with the upper edge of the
installation plate) Ensure that the hooks are properly
seated on the installation plate by moving it left and
right
2. Unlock the tubing holder from the chassis and mount
between the chassis and installation plate in order to
separate the bottom side of the indoor unit from the
wallwall
Piping
1. Insert the connecting cable through the bottom side of indoor unit and connect the cable (You can see detail
contents in 'Connecting the cables' section)
<Left side piping>
View
2. Secure the cable onto the control board with the cable retainer.
3. Tape the tubing pipe, drain hose and the connection cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper side can cause overflow from the drain pan through the
inside of the unit.
Terminal block
Connecting cable
Cable retainer
Inverter Single
Inverter Single
Inverter Single
Inverter Single
Installation plate
Tubing Holder
<Right side piping>
View
Terminal block
Connecting cable
Cable retainer
Installation
67