Transmitter Section
Item
Condition
1. Frequency
1) Set test mode
Select "FREQ" in tuning mode. F. counter panel
PTT : ON
Adjust [_ ** ]
2. Power
1) Maximum power
output
Set test mode
Select "HPOW" in tuning mode.
"H.POW"
Adjust [256]
PTT : ON
3. High power
1) Set test mode
Select "HPOW" in tuning mode.
"H.POW"
PTT : ON
Adjust [ *** ]
2) "H.P.OW"
PTT : ON
Adjust [ *** ]
3) "H.P.O.W"
PTT : ON
Adjust [ *** ]
4) "H.P.O.W."
PTT : ON
Adjust [ *** ]
5) "H.P.O.W._."
PTT : ON
Adjust [ *** ]
4. Low power
1) Set test mode
Select "LPOW" in tuning mode.
"L.POW"
PTT : ON
Adjust [ *** ]
2) "L.P.OW"
PTT : ON
Adjust [ *** ]
3) "L.P.O.W"
PTT : ON
Adjust [ *** ]
4) "L.P.O.W."
PTT : ON
Adjust [ *** ]
5) "L.P.O.W._."
PTT : ON
Adjust [ *** ]
5. Power check 1) Set test mode
CH : CH1 - Sig1
CH2 - Sig1
CH3 - Sig1
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Front
panel
Power mete
Power meter Rear
ANT
panel
Ammeter
DC IN
TK-860HG/862HG
Adjustment
Parts
Method
CH /
Check
470.100MHz±100Hz K,M
498.600MHz±100Hz K2
415.100MHz±100Hz K2,M3
Check
More than 42.0W
± 2.0W
40.0W
± 1.0W
10.0W
Check
40W±2W, 12A or less
Specifications/Remarks
27