CAPACITOR
1. Remove the screw and open the
top cover of the control box.
2. Discharge the capacitor by
shorting it with a 20KΩ resistor.
3. Disconnect the leads.
4. Replacement is the reverse of
these steps.
POWER CORD
1. Remove the screw and open the
top cover of the control box.
2. Disconnect the front panel from
the control box by prying the tab
open and folding it to the left.
3. Discharge the capacitor (above).
4. Disconnect the leads from the
capacitor and relay.
5. Pull the power cord free.
6. Replacement is the reverse of
these steps.
7. If the cord is damaged or
compromised in any way, it must
be replaced with an exact
replacement part, including any
protective devices, rather than
by a generic cord.
8. Use only a single point ground
connection for all ground wires
at this location.
LWHD1006R
Page 21 of 40
Training Manual