8.3.1.8.
Airflow Direction
1. There is one type of airflow, vertical airflow (directed by horizontal vane).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature
and intake air temperature) and manual (angles of direction can be adjusted using remote control).
Vertical Airflow
Operation Mode
Heating
Cooling, Soft Dry and Ion
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1
below. When the air conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the
positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to
close position.
Airflow Direction
Auto with Heat Exchanger
Temperature
Manual
Auto
Manual
68
A
Upward fix
B
Downward fix
C
Downward fix
D
Downward fix
Vane Angle (°)
1
2
3
4
161
161
197
197
197
26 ~ 49
49
5
161
26