SELECTING THE MOUNTING
POSITION
Decide the mounting position with the customer as follows:
(1) If possible, do not install the unit where it will be exposed to direct sunlight.
(If necessary, install a blind that does not interfere with the air fl ow.)
(2) Do not install the unit where a strong wind blows or where it is very dusty.
(3) Do not install the unit where people pass.
(4) Take your neighbors into consideration so that they are not disturbed
by air blowing into their windows or by noise.
(5) Provide the space shown in the fi gure so that the air fl ow is not
blocked.
Also for effi cient operation, leave open three of the four directions
front, rear, and both sides.
Install at a place that can withstand the weight of the
outdoor units and install positively so that the units will
not topple or fall.
(1)
Do not install where there is the danger of combustible gas
leakage.
(2)
Do not install near heat sources.
(3)
If children under 10 years old may approach the unit, take
preventive measures so that they cannot reach the unit.
POWER
(1)
The rated voltage of this product is 208/230 V AC 60 Hz.
(2)
Before turning on the power, check if the voltage is within the
208 V -10 % to 230 V +10 % range.
(3)
Always use a special branch circuit and install a special receptacle
to supply power to the room air conditioner.
(4)
Use a circuit breaker and receptacle matched to the capacity of
the air conditioner.
(1)
The power source capacity must be the sum of the air conditioner current and the current of other electrical appliances. When the cur-
rent contracted capacity is insuffi cient, change the contracted capacity.
(2)
When the voltage is low and the air conditioner is diffi cult to start, contact the power company the voltage raised.
WARNING
CAUTION
INSTALLATION DIAGRAM OF
OUTDOOR UNIT
Connection Cord
14AWG
[OUTDOOR UNIT]
24" (60 cm) or over
4" (10 cm) or over
8" (20 cm) or over
• Do not directly install it on
the ground, otherwise it
will cause failure.
• To obtain better operation
efficiency, when the outdoor
unit is installed, be sure to
open the front and left side.
(1) When the outdoor temperature is 32 ° F (0 ° C) or less, do not use the accessor y
drain pipe and drain cap. If the drain pipe and drain cap are used, the drain water
in the pipe may freeze in extremety cold weather. (Reverse cycle model only).
(2) In the area with heavy snowfall, if the intake and outlet of outdoor unit is
blocked with snow, it might become diffi cult to get warm and it is likely
to because of the breakdown. Please construct a canopy and a pedesta or
place the unit on a high stand (local confi gured).
21-9/32 " (54 cm)
WARNING
(5)
Do not extend the power cable.
(6)
Perform wiring work in accordance with standards so that the
air conditioner can be operated safely and positively.
(7)
Install a leakage circuit breaker in accordance with the related
laws and regulations and electric company standards.
CAUTION

INDOOR UNIT

4" (10 cm)
or over
2" (5 cm) or over
Outdoor unit bottom
Drain hose
CAUTION
Installation instruction on the back.
10" (25 cm)
or over