3

Dimensional drawings

FCQ-B7
Model
A
B
FCQ35B
6.35
9.52
FCQ50B, FCQ60B
6.35
12.70
Note 3
Hanging bolt
Note:
1. Location of unit's name plate
Main body: bell mouth inside the suction grille.
Decoration panel: panel inner frame inside the suction grille..
2. When installing an optional accessory, refer to the installation drawings.
+ For fresh air intake kit - inspection port is necessary
+ For high efficiency filter unit - inspection port is not necessary.
+ For branch duct chamber - inspection port is not necessary.
• 4-Way Blow Ceiling Mounted Cassette • R-410A • FCQ35-60B7V1B
Prepared hole
For fresh air intake kit connection (direct installation type)
view C
300 or less
view A
3. In case of using an infrared remote control, this position will be a signal
receiver.
Refer to the drawing of infrared remote controller in detail
4. When it may exceed 30°C and RH 80% in the ceiling or fresh air is
inducted into the ceiling, an additional insulation (Thickness 10mm or
more of glasswool or polyethylene form) is required.
• Split - Sky Air • Indoor Units
860∼890 (Ceiling opening)
680 Suspension position
view B
1500 mm or more
1500 mm or more
Prepared hole
Branch duct
connection
1
Liquid pipe connection JA Flare connection
2
Gas pipe connectionJB Flare connection
3
Drain pipe connection VP25 (O.D. J 32, I.D. J 25)
4
Power supply connection
5
Transmission wiring connection
6
Air discharge grille
7
Air suction grille
8
Water supply intake
9
Corner decoration cover
10
Drain hose O.D.J32
Prepared hole
Branch duct
connection
Prepared hole
Branch duct connection
view D
1500 mm or more
1500 mm or more
Required installation space
When the discharge grill is closed, the required
space is 200mm or more
3TW22834-1A