Faceplate & Trim Installation - Regency U41 Owners & Installation Manual

Gas insert
Hide thumbs Also See for U41:
Table of Contents

Advertisement

INSTALLATION
temperature and shut down the
gas valve in the event of a severe
downdraft of air or a blocked or
disconnected vent. The switch
acts as a safety shut-off to pre-
vent a build up of carbon monox-
ide. If the flue is blocked or has no
"draw", the switch will automati-
cally shut off the supply of gas
within 5 - 10 minutes. Tampering
with the switch can result in car-
bon monoxide (CO) poisoning and
possible death.
If the heater turns off because of
lack of draft during the spillage
test, check for the cause and if
necessary, seek expert advice.
The thermally actuated safety
switch will automatically reset
after it has reduced in tempera-
ture. The switch will continue to
cycle until the draft problem is
corrected. DO NOT BYPASS OR DIS-
CONNECT THIS SWITCH.
FACEPLATE AND TRIM
INSTALLATION
Hint:
Before doing the faceplate installa-
tion, leave the Insert out approximate-
ly 4" so wires may be hooked up more
easily.
1) Lay the faceplate panels flat, face down on
something soft so they don't scratch.
2) Take the top faceplate and align the holes
in it with the holes in the side panels.
Attach, using the screws provided. See
diagram 1.
Diagram 1
Note: The holes in the top panel are slight-
ly larger than the holes in the side
panel to facilitate easier installa-
tion.
Hint: Don't tighten the screws down complete-
ly at this point, first do a trial fit to the unit. Make
any necessary adjustments and when it fits
properly then tighten down the screws.
10
3) Using the trim clips provided, join the left
side gold trim (the one with the ON/OFF
switch and variable speed FAN switch) to
the top gold trim. See diagram 2. Repeat this
step for right side.
Diagram 2
4) Place the trim on the assembled faceplate
panels, aligning the wires from the switch-
es with the notch in the left side faceplate
panel.
The power cord should be run behind the
faceplate panel.
5) Push the Regency logo plate into the two
holes in the bottom left corner of the face-
plate.
6) Secure the brass trim to the faceplate by
drilling a 1/8" hole through into the faceplate
side flange, using the hole in the brass trim
as a guide. Now fasten with the two brass
plated screws provided.
7) Lift the assembled faceplate up and over
the top of the insert and then lower it down
so the faceplate tabs are in line with the
faceplate brackets. See diagram 3. Once
everything is properly lined up you can
tighten the 4 screws on the faceplate
brackets. See diagram 4.
Diagram 3
Note: If you are making custom face-
plates, you must use the faceplate
louvers. Failure to do so will void
the certification on your unit. The
faceplate louvers can be purchased
separately.
Diagram 4
8) Fan Switch wires: Connect the plug end
from the fan switches to the matching plug
from the unit. See Diagram 5. Make sure the
plugs are pushed together as far as they
can go. Push the connection into the hole in
the side of the insert so it is locked into place.
9) ON/OFF wires: Hook up the ON/OFF wires
to the switch on the left side trim. Diagram
5.
Diagram 5
Regency U41-3 ULTIMATE Gas Fireplace Insert

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents