OPTION SETTING

1
MAIN MENU
LANGUAGE
SET
CAMERA ID
OFF
SYNC
INT
PRIVACY MASK
SET
LENS
SET
MIRROR
OFF
VIEW SETTING
1
OPTION
SET

CONTROL setting

1
Use the cursor button (j or l) to move the cursor to
OPTION, then press the SET button.
The OPTION screen will appear.
Note: The PRESET ON setting cannot be used when OPTION
settings are in use.
2
Use the cursor button (j or l) to move the cursor to
485 for CONTROL, use the cursor button (d or c) to
select the device to be operated (Ex: 485), and then press
the SET button.
The RS-485 SETTING screen will appear.
Available settings:
• 485: For operation by the System Controller and Camera
Control Unit VAC-70.
• COAX: For operation of device by linked coax cable.
2
OPTION
CONTROL
485
ADDRESS
0
ALARM
SET
3
RS-485 SETTING
BAUD RATE
19200
TERMINATE
OFF
3
Use the cursor button (d or c) to select 19200 for BAUD
RATE.
Available settings: 19200, 9600, 4800, 2400
4
Use the cursor button (j or l) to move the cursor to
TERMINATE, and then use the cursor button (d or c) to
select the terminate setting.
To close the menu screen or return to the previous
screen, select BACK or END for MENU and press the SET
button.
4
RS-485 SETTING
BAUD RATE
19200
TERMINATE
OFF