Napoleon EPA 1450 Installation And Operation Instructions Manual
Napoleon EPA 1450 Installation And Operation Instructions Manual

Napoleon EPA 1450 Installation And Operation Instructions Manual

Napoleon fireplace installation and operation instructions

Advertisement

CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE
EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482. MODEL
EPA 1100, 1100L, 1100C, 1150,
1400, 1400L, 1450 & 1900
FREE STANDING MODELS
EPI 1101, 1402

SAFETY INFORMATION

If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage, bodily injury or even death. Please read
entire manual before you install and use your fireplace.
This fireplace has not been tested with an unvented gas log set. To reduce
risk of fire or injury, do not install an unvented gas log set into the fireplace.
- This fireplace can be very hot when burning.
- Combustible materials such as firewood, wet clothing, etc. placed too close can catch fire.
- Children and pets must be kept from touching the fireplace when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit, contact the local
building or fire authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the firebricks.
- Do not use an elevated grate or otherwise raise the fire.
- At least 14 square inches of outside air must be admitted to the room or directly to the unit
through a 4" diameter pipe.
- This fireplace is designed to burn natural wood only. Higher efficiencies and lower emissions
generally result when burning air dried seasoned hardwoods, as compared to softwoods or
to green or freshly cut hardwoods.
- Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard, solvents or garbage.
- Do not let the fireplace become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to acheieve
heat output rates that exceed design specifications can result in steel distortion and
damage.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada (705)721-1212 fax(705)722-6031
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE
1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
INSERT MODEL
WARNING
!
www.napoleonfireplaces.com ask@napoleon.on.ca
INSTALLATION
AND OPERATION
INSTRUCTIONS
1
W415-0512 / D / 07.16.08
W415-0512 / D / 07.16.08

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon EPA 1450

  • Page 1: Safety Information

    INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
  • Page 2: Table Of Contents

    2-4 INTRODUCTION Warranty General Information Care of Plated & Enamelled Parts Care of Glass 5-6 INSTALLATION Installing the Legs Alcove Installation Stove Installation Chimney Connection Adding Chimney Sections Outside Air Wall Pass-through 6-7 MOBILE HOME Venting Outside Air 7-8 FIREPLACE INSERT Prior to Installation Installation into a Masonry Fireplace Installation into a Factory Built Fireplace...
  • Page 3 NAPOLEON® products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fi replace is thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON®.
  • Page 4: General Information

    GENERAL INFORMATION Except for their different depths, models 1100, 1150, 1400, 1900, 1450 and the fi replace inserts 1101, and 1402 are identical and use the same burning principles. They were specifi cally designed over many months of research to meet the 1990 U.S.A.
  • Page 5: Installation

    STOVE INSTALLATION INSTALLING THE LEGS To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed. 1. Remove the 4 nuts and wash- ers from the underside of the pallet.
  • Page 6: Adding Chimney Sections

    THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE. All horizontal smoke pipe must slope slightly upwards a minimum of 1/4” per foot (6mm/0.3m) and all connections must be tight and secured by three sheet metal screws equally spaced.
  • Page 7: Outside Air

    FIGURE 11 It must be installed between ceil- ing joists, with radiation shield and roof flashing, so that the structural strength, insulation and waterproof qualities of the home are not lessened. Seal with sili- cone to maintain a vapour barrier at the chimney and outside air pipe penetrations.
  • Page 8: Optional Blower

    In the United States: While it is not required, it is recom- mended that a chimney liner be installed that is continuous from the insert to the top of the chimney, particularly when the insert is installed in a basement. For this type of connection, use the “In Canada”...
  • Page 9: Blower Service And Replacement

    3. The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16” nut driver will be required to complete this job. Unplug wires from the thermal switch on the panel. See FIGURE 15. 4. Remove the securing wingnut from the blower mounting bracket, slide the bracket to the right and rotate the left side of the assembly out of the cavity to clear the blower motor.
  • Page 10: Finishing

    SIZES 1-1/4” x 4”-1/2 x 9” 1-1/4” x 3” x 9” 1-1/4” x 4-1/2” x 4-1/2” 1-1/4” x 4-1/2” x 9” 1-1/4” x 2-1/2” x 4-1/2” 1-1/4” x 1-1/2” x 4-1/2” 1-1/4” x 4-1/2” x 9” (light weight) 1-1/4” x 2-1/4” x 9” 1-1/4”...
  • Page 11: Ornamental Trivet Installation

    BRICKS AND BAFFLES INSTALLATION With stove and chimney installation completed, move the bricks into place by working as illustrated for your unit on page 10. 1. Install two or three courses of brick on both sides of the unit. Install two courses on the back wall. Install the fi nal course of bricks on the back wall.
  • Page 12: Achieving Proper Draft

    You can now add larger pieces of wood and operate the stove normally. Once the stove/insert is entirely hot, it will burn very effi ciently with little smoke from the chimney. There will be a bed of orange coals in the fi rebox and secondary fl ames fl...
  • Page 13: Smoking

    SMOKING A properly installed Napoleon unit should not smoke. If yours does, check the following: Has the chimney had time to get hot? Is the smoke passage blocked anywhere in the stove, chimney connector or chimney? Is the room too airtight and the air intake not connected to the outside? Try with a win- dow partly open.
  • Page 14: Wood Pile Maintenance

    DOOR REMOVAL (1100C ONLY) 1. Remove cast top. 2. Pull pin from top door hinge. It is important to hold the door while removing the pin. Pivot the door to clear the top door hinge. Lift the door off of the lower pin. Do not pivot the door any further than necessary.
  • Page 15: Replacements

    Contact your dealer for questions concerning prices and avail- ability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: FOR WARRANTY REPLACEMENT PARTS ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM REPLACEMENT PARTS PART NO.
  • Page 16 PART NO. DESCRIPTION H222G GOLD PLATED DOOR H222 BLACK DOOR H222SS BRUSHED STAINLESS STEEL DOOR STANDARD ARCH H222W BLACK DOOR - H222GW GOLD DOOR - H222SSW BRUSHED STAINLESS STEEL DOOR EARLY AMERICAN W010-1071 DOOR GLASS W020-0043 DOOR GASKET W020-0050 GLASS GASKET CISK** CAST IRON SURROUND KIT, CISK...
  • Page 17 W415-0512 / D / 07.16.08...
  • Page 18 W415-0512 / D / 07.16.08...
  • Page 19 NOTES W415-0512 / D / 07.16.08...
  • Page 20 NOTES W415-0512 / D / 07.16.08...
  • Page 21 W415-0512 / D / 07.16.08...

Table of Contents