Thermal head and platen roller
1. Unplug your fax machine.
2. Press the top cover release, located on the right side of the machine, to open
the top cover.
3. Clean the thermal head as illustrated using a soft cloth moistened isopropyl
alcohol.
Note: Do not use abrasive materials on the surface of the thermal head.
4. Use a soft, lint-free cloth moistened with a mild cleaner to clean the platen
roller. Rotate the roller to clean all its surfaces.
5. Firmly close the cover slowly after pulling it up until it stops.
Contact glass, separator pad, separator roller and TX feed
roller
1. Unplug your fax machine.
2. Press the top cover release, located on the right side of the machine, to open
the top cover.
3. Use a soft, lint-free cloth moistened with isopropyl alcohol to clean the surface
of the contact glass.
4. Use a soft, lint-free cloth moistened with a mild cleaner to clean the separator
pad, separator roller and TX feed roller. Rotate the rollers to clean all its
surfaces.