General Configuration
SNTP Client:
Server:
Polling Time:
Time Zone Configuration
Time Zone:
Time Zone Offset:
Daylight Configuration
Daylight Saving:
Daylight Saving Offset:
Multi-Tech Systems, Inc. MultiModem Wireless Modem with Ethernet Interface (S000375B)
Enable or disable the SNTP Client to contact the configured server on the UDP port 123
and set the local time. The default is Disable.
Enter the SNTP server name or IP address to which the SNTP Client must contact in
order to update the time. No default.
Enter the polling time at which the SNTP client requests the server to update the time.
Default is 300 minutes. Time must be entered in minutes.
Enter your time zone. Default = UTC (Universal Coordination).
See the following Web site for Time Zone information:
http://wwp.greenwichmeantime.com/info/timezone.htm
Enter +/- hh:mm. Default = +00:00. Offset is the amount of time varying from the
standard time of a Time Zone.
Enables/disables Daylight Saving mode. The default is Enable.
Set the offset to use during Daylight Saving mode. Default is +60 minutes.
Enter the time in + / - minutes.