FUNCTION SETTING
Outlet direction selection
z
Performs operation matched to the number of outlets when 4 directions are unnecessary and
outlets are blocked when the ceiling cassette is installed in a corner, etc.
4-way direction
3-way direction
Ceiling switching function
z
Also delivers air to high ceilings by selecting the mode and raising the air flow according to the
height of the ceiling.
High ceiling (Mode 2)
*1
4.2m
*1 : AU*A30L is 3.6m
Standard ...Operates at normal air flow.
Mode 1 ...Air flow becomes smaller than normal.
Mode 2 ...Air flow becomes greater than normal.

Filter sign

z
The indoor unit has sign to inform the user that it is time to clean the filter
Cooling room temperature correction
z
Heating room temperature correction
z

Auto restart

z
The units restart automatically when the current was returned even when there was a power
interruption during operation.
Room temperature sensor switching
z
Switches from room temperature judgment by room temperature sensor attached to indoor
unit body to room temperature judgment by room temperature sensor attached to wired remote
controller.

Economy operation

z
The power consumption can be reduced.
Powerful mode ...Standard
Soft mode ...Performs operation which reduces the power consumption
4-way direction mode: Set when there are 4 outlets
(shipped state).
3-way direction mode: Set when there are 3 outlets.
Standard ceiling (Standard)
3.2m
- (01 - 03) -
Low ceiling (Mode 1)
2.7m

Advertisement