FUNCTION SETTING
Outlet direction selection
•
Performs operation matched to the number of outlets when 4 directions are unnecessary and
outlets are blocked when the ceiling cassette is installed in a corner, etc.
4-way direction
3-way direction
Ceiling switching function
Air reaches sufficiently up to 3m height, even it is compact cassette type.
Also delivers air to high ceilings by selecting the mode and raising the air flow according to the
height of the ceiling.
High ceiling (Mode 1)
3m
Standard ...Operates at normal air flow.
Mode 1 ...Air flow becomes greater than normal.
Filter sign
The indoor unit has sign to inform the user that it is time to clean the filter
Cooling room temperature correction
Heating room temperature correction
Auto restart
The units restart automatically when the current was returned even when there was a power
interruption during operation.
Room temperature sensor switching
Switches from room temperature judgment by room temperature sensor attached to indoor
unit body to room temperature judgment by room temperature sensor attached to wired remote
controller.
Economy operation
The power consumption can be reduced.
Powerful mode ...Standard
Soft mode
...Performs operation which reduces the power consumption
4-way direction mode: Set when there are 4 outlets
(shipped state).
3-way direction mode: Set when there are 3 outlets.
Standard ceiling (Standard)
2.7m
- (01 - 03) -