Haier HP200M2 Installation And Service Manual page 14

Heat pump water heater
Hide thumbs Also See for HP200M2:
Table of Contents

Advertisement

- Remove vent grid first.
- Install diameter 160mm duct.
- Pressure drops from duct must be lower than or equal to the static pressure of the fan.
- If the pressure drops out of range, the performance of the appliance will be impaired.
Maximum length of the air connection 5m (Diameter of air connection 160 mm).
c. Advised positions
Garage or laundry room (without ducts):
-Unheated room.
-Enables recovery of the free energy released by your vehicle's engine when switched off after use
or by household appliances in operation.
Laundry room (with one duct):
-Unheated room.
-Enables recovery of the free energy released by your vehicle's engine when switched off after use
or by household appliances in operation.
-Referring installer menu, adjust the fan speed.
14