3. Installing the indoor unit
A24, A30
(inch)
3) InstaMng
the wall mounting
fixture
\\\\\
=,
=, IM,n231
Min.G1/2
A36
...........................................
f .....................................
M}n.GI/2
Fig. 3=4
Max. 19/32
Fig. 3=5
Since
the indoor
unit
weighs
near
30 kg,
66 Ibs, selection
of the mounting
location
requires
thorough
consideration.
If the
wall
does
not
seem
to be
strong
enough,
reinforce
it with
boards
or beams
before
installation.
The
mounting
fixture
must
be secured
at both
ends
and
at the centre,
if
possible.
Never
fix it at a single
spot
or in any nonsymetrical
way.
(if possible,
secure
the fixture
at all the positions
marked
with a bold
arrow.)
(Fig.
3-4)
Secure
the
wall
mounting
fixture
through
its middle
row
of 12-mm,
t/2
inch-dia,
holes
using
locally
purchased
bolts
(through
bolts,
bolt
anchor
and
nut anchor)
of Mr0
or W3/6
threading.The
bolt tip must
not protrude
by
more
than
15 ram, 9/32
inch from
the wall
surface.
(Fig.
3-5)
Use at least
two bolts
for a concrete
wall,
and at least
four
bolts
for a foamed
concrete
wail
_A_Wall-fixing bracket
_B_ Mounting bolt
_C_ Wall
Z_ Warning:
if possible,
secure
the fixture
at all the positions
marked
with
a bold
arrow.
Z_ Caution:
The unit body
must
be mounted
horizontally,
3.3. Preparation for piping connection
Remove
the vinyl band that holds
the drain piping.
• This
vinyl band
can be used to temporarily
attach
the pipes
to the wall mounting
fixture
while
connecting
the left pipe.
1) Rear,
right
and
lower
piping
(Fig.
3-6)
1® Remove
the right
side panel.
Fig. 3=6
Fig. 3=7
®
®
®
Fig. 3=8
2) Left
and
left rear piping
®
Remove
the side panel.
When
embedding
pipes
into
the
wall
(Fig.
3=7)
When
the refrigerant
pipe, drain pipes,
internal/external
connection
lines,
etc., are to
be embedded
into the wall in advance,
the extruding
pipes,
etc., may have to be bent
and have their
length
modified
to the unit.
• Make the pipes
to be embedded
slightly
longer
than
necessary,
and install.
_A)Right side panel
(C)On-site piping
_) Through hole
CD) W all-fixing bracket _
®
Remove
the five screws
indicated
by the arrows
in the diagram.
(Fig. 3-8)
®
Remove
the left side panel,
then the lower
panel.
1. While
pushing
up the front lower portion
of the side panel
(to disengage
the side
panel
catch
from the unit catch),
slide
the upper
portion
of the side panel
to the
left.
• When
the indoor
unit is already
mounted,
be sure the unit does not fall from the wall
mounting
fixture.
• For reassembly,
put the catch
at the front
lower
portion
of the side panel
over the
unit body and push it to the right.
_A)Grille
(_ Catch
_) Left side panel
_) Side panel
(C) Lower panel
(_ Unit body
_: Structure
of the side panel
and the unit body
(Fig. 3-9)
1. Panel
catch engages
the unit body catch.
2. Panel
catch is put in the unit body
hole.
3. Panel
catch engages
the unit body catch.
4. Sheet
metal
of the unit body enters
the panel.
5. Panel
catch enters
the unit body hole.
®
The drain hose can be connected
at two different
positions.
Use the most conven-
ient position
and,
if necessary,
exchange
the position
of the drain pan,
rubber
plug
and the drain
hose. (Fig. 3-10)
@ Drain pan
_) Band
Plug
_J) Drain hose
(© Screwdriver
4
Fig. 3=10