Check of anomalous operation data with the remote
controller
Operation data can be checked with remote control unit operation.
➀ Press the
button.
The display change "
➁ Press the
(SET) button while "
➂ When only one indoor unit is connected to remote controller,
"
" is displayed (blinking indication during data
loading).
Next, operation data of the indoor unit will be displayed. Skip to step ➆ .
➃ When plural indoor units is connected, the smallest address number
of indoor unit among all connected indoor unit is displayed.
[Example]:
"
" (blinking 1 seconds) ➝ "
blinking.
➄ Select the indoor unit number you would like to have data displayed
with the
button.
➅ Determine the indoor unit number with the
(The indoor unit number changes from blinking indication to
continuous indication)
"
" (The address of selected indoor unit is blinking for 2
seconds.)
"
" (A blinking indication appears while data loaded.)
Next, the operation data of the indoor unit is indicated.
➆ Upon operation of the
displayed in order from data number 01.
The items displayed are in the above table.
*Depending on models, the items that do not have corresponding data are not displayed.
➇ To display the data of a different indoor unit, press the
selection screen.
➈ Pressing the
Pressing the
(RESET) button during remote control unit operation will undo your last operation and allow you to go back to
the previous screen.
 If two (2) remote controllers are connected to one (1) inside unit, only the master controller is available for trial operation and
confirmation of operation data. (The slave remote controller is not available.)
"
(SET) button.
button, the current operation data is
button will stop displaying data.
Number
01
02
03
04
" is displayed.
05
06
07
08
09
10
11
12
21
22
"
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
button, which allows you to go back to the indoor unit
263
Data Item
(Operation Mode)
(Set Temperature)
(Return Air Temperature)
(Remote Controller Thermistor Temperature)
(Indoor Unit Heat Exchanger Thermistor / U Bend)
(Indoor Unit Heat Exchanger Thermistor /Capillary)
(Indoor Unit Heat Exchanger Thermistor /Gas Header)
(Indoor Unit Fan Speed)
(Frequency Requirements)
(Response Frequency)
(Pulse of Indoor Unit Expansion Value)
(Total Running Hours of The Indoor Unit)
(Outdoor Air Temperature)
(Outdoor Unit Heat Exchanger Thermistor)
(Outdoor Unit Heat Exchanger Thermistor)
(Compressor Frequency)
(High Pressure)
(Low Pressure)
(Discharge Pipe Temperature)
(Comp Bottom Temperature)
(Current)
(Target Super Heat)
(Super Heat)
(Discharge Pipe Super Heat)
(Protection State No. of The Compressor)
(Outdoor Unit Fan Speed)
(63H1 On/Off)
(Defrost Control On/Off)
(Total Running Hours of The Compressor)
(Pulse of The Outdoor Unit Expansion Valve EEVC)
(Pulse of The Outdoor Unit Expansion Valve EEVH)