Digital Controller Operation - Keltech CNA-36 Installation Manual

Cna-series tankless heater
Table of Contents

Advertisement

CNA-Series Tankless Heater
6

Digital Controller Operation

The preprogrammed digital controller is mounted through the bezel on the enclosure door. The digital
controller will be powered but the bottom display will read OFF until water is flowing through the heater.
The bottom display will then display the setpoint temperature (See Digital Controller Operation section for
more information).
Description
EZ Key
Setpoint Up Button
Setpoint Down Button
Infinity Key
Advance Key
Output Indicators (1-5)
Setpoint Temperature
(Lower Display)
Output Temperature
(Upper Display)
Layout Diagram
EZ Key
Infinity Key
Advance Key
10
Upper Display
Lower Display
Auto, Man, Off
XX .X%
no
C or F
ON - Heating
Output Indicators
1
2
Output Temp .
3
4
Setpoint Temp .
5
Setpoint Up
Setpoint Down
7/13/2015
Function
Toggles output on/off
Increases output temperature
Decreases output temperature
Back to Home page
Advances through parameter prompts
C .r71
Turns Control Loop On/Manual/Off
h .Pr1
Heater Power %
AUt1
Autotune (Contact Factory)
C_F1
Change Temperature Units from F to C
Output 1,2,3,4 or 5 are active and operating if
these LEDs are illuminated .
Displays:
• Setpoint
• Percent Power
• Temperature units F or C
• Menu prompt name
• Alarm code
Displays:
• Actual process temp . of outgoing water
• Prompt parameter value
• Error code (feature disabled)
1
Output
2
Temp .
3
Setpoint
4
Temp .
5
OFF - No Flow
Keltech • 215-1814 Rev. C; ECN 150010
Installation
1
Output
2
Temp .
3
4
No Flow
5

Advertisement

Table of Contents
loading

Table of Contents